Shanghai Jianzhi Electric Technology Co., Ltd.

Home >> Product >>STEERING PUMP ASSEMBLY >> 1.5KW permanent magnet synchronous steering pump assembly
Product Detail

1.5KW permanent magnet synchronous steering pump assembly

Collect
  • Product introduction

ͼƬ7.png

Features

High reliability

Low noise and high safety

Lightweight and small

Double insulation design

High degree of protection


Scope of application

New energy electric minibuses, large buses, electric buses, electric trucks, electric sanitation, electric logistics, etc.; wide coverage: the power ranges from 1kW-4kW, which can cover all the steering assist requirements of new energy vehicles.


 


 


technical parameter


Technical parameters of steering pump assembly

model

EHPS-1.5R1011B02

Controller voltage range£¨VDC£©

400-700

Rated voltage£¨VAC£©

227

Rated frequency£¨Hz£©

140

rated power£¨KW£©

1.5

Peak power£¨KW£©

3

Rated current£¨A£©

5.5

Rated speed£¨r/min£©

1680

Rated torque£¨N.m£©

8.68

Peak torque£¨N.m£©

16.73

Work system

S2-3min

Motor type

Permanent magnet synchronization

Insulation class

H level

Protection level

IP67

cooling method

Natural cooling

Working temperature

-40¡æ - 80¡æ

Oil pump parameters

model

FZB115A3A

Displacement£¨ml/r£©

6.6

flow£¨L/min£©

11

greatest pressure£¨MPa£©

10-11

Control flow£¨L/min£©

1000r/min 0.5MPA

 

1. The steering oil pump assembly should meet the requirements of QC/T 299 "Technical Conditions for Automotive Power Steering Oil Pumps";

2. No mechanical drive shock phenomenon is allowed when the assembly is working;

3. Measure the noise at a position 1000mm away from the front of the assembly. When running at no load, the assembly noise is less than 65dB;

4. The stay time when the steering wheel turns to the limit position is not allowed to exceed 10s, and the system does not allow over-current protection to stop;

5. There is a reliable grounding protection wire interface on the surface of the motor, which must be effectively grounded after installation;

6. The steering gear needs to be equipped with a stroke unloading valve, and the stroke opening pressure at the limit position of the direction is less than 5MPa;

7. When wiring, the phase sequence corresponds to the position of the plug-in unit. At this time, from the direction of the pump head, the direction of rotation of the motor is counterclockwise (left-handed), otherwise the direction of rotation of the motor is opposite, and the steering pump does not work.

8. Working environment temperature: -40¡æ+80¡æ;

9. The appearance is clean and tidy, free of foreign matter, dirt, damage and other defects, and the joint surface between the assembly and the parts is good, and there is no air leakage, no oil leakage, etc.;

10. Add dust cover to the oil inlet and outlet to prevent pollution during transportation and storage;

11. Install the damping pad with the assembly

Navigation